| Availability: | |
|---|---|
| Quantity: | |
Hi2800
HuaHe
Burned VFD control boards, construction-site laptop crashes, sudden PLC faults mid-operation — the usual suspect isn't insufficient wattage. It's poor power quality.
The HH168-2 delivers a total harmonic distortion (THD) of ≤3%, fully compliant with ISO 8528 G1, the international standard for precision-grade AC power output. For B2B buyers, this translates directly to:
Zero supplementary voltage regulators required for inverter ACs, medical analyzers, or industrial PLCs
Eliminating liability exposure from sensitive equipment damage claims
Specification-ready compliance documentation for tenders requiring ISO 8528 G1
Specification
| Value | What It Means for Your Business | |
Rated Power | 2500W | Runs 1.5HP AC + site lighting simultaneously |
Max Power | 2800W | ≥12% surge headroom — motor start-ups won't trip the breaker |
THD | ≤3% | ISO 8528 G1 precision power — approved for sensitive electronics |
Displacement | 196CC | Higher low-RPM torque vs. 163CC competitors; better efficiency under load |
Fuel Tank | 5.5L | ~3 hours at rated load — covers a full site shift |
Noise Level | ≤97dB (at 7m) | Open-frame design, optimized for outdoor and mobile applications |
Net Weight | 24.3kg | Single-operator portable — no forklift or extra labor required |
Starting System | Manual + Electric | Dual-mode flexibility for varied environments and operator preferences |
Dimensions | 470×390×470mm | Compact footprint for pallet-stacked container loading |
Profile 1 | Construction Equipment Distributors
End customers need a generator that one person can deploy without assistance. At 24.3kg with a compact open frame and dual-start options, this unit eliminates the "need two guys just to start the generator" complaint — and gives your clients a legitimate reason to re-order from you.
Profile 2 | OEM Solution Packagers
Bundling portable power with your product offering? The 470×390×470mm footprint enables denser pallet arrangements — approximately 8% more units per 20ft container compared to typical 200CC-class units. Less freight cost per unit means better landed-cost positioning for your customers.
Profile 3 | Industrial Export Intermediaries
European procurement officers routinely screen generator specs for harmonic compliance before approving supplier lists. The HH168-2's ISO 8528 G1 status eliminates a round of technical review, shortening your client's qualification timeline and positioning you as a compliant, documentation-ready supplier.
Purchase price is one number. Total Cost of Ownership (TCO) is another.
The HH168-2 runs a 196CC, four-stroke overhead-valve engine — a larger displacement than the 163CC units that dominate the lower end of this power bracket. The operational difference:
163CC engines compensate with higher RPM → greater heat, faster wear, higher fuel burn per kWh
196CC at rated 2500W output ≈ 1.8L/hour fuel consumption — a meaningful difference over a 250-day operating year
Lower annual fuel and maintenance costs = a stronger re-order argument your clients will feel in their P&L
Overload Protection: Frequency-converter-based overcurrent program control — not a simple mechanical breaker. The unit responds to current anomalies in milliseconds, protecting both the generator and the connected load.
Ignition System: F7RTC / FTTC spark plug — a cross-compatible specification stocked by major parts distributors in Southeast Asia, the Middle East, and Latin America. Maintenance continuity is never a sourcing issue for your clients.
Operating Altitude: Rated to ≤1,000m. For high-altitude deployments (Andes, East Africa, Central Asian plateaus), contact us for high-altitude carburetor calibration options.
Fuel Compatibility: Runs on standard commercial unleaded gasoline — no proprietary blends, no import complications regardless of destination market.
Q: Can the inverter output maintain a stable 50Hz for CNC machines or variable-frequency drives? A: Yes. The inverter module actively regulates output frequency to 50Hz ±0.5% with THD ≤3%. This meets ISO 8528 G1 thresholds required by most industrial and medical equipment OEMs.
Q: What battery specification is required for electric start? A: A standard 12V lead-acid battery with >=7Ah capacity. For ambient temperatures below 5°C (41°F), manual start is recommended for reliable cold cranking.
Q: Is OEM/private-label branding available? A: Yes. Above MOQ thresholds, we offer chassis silk-screen branding, custom carton printing, and localized user manual production. Send your specs and we'll provide a branding cost breakdown within 48 hours.
Q: What certifications are available for EU or US market entry? A: Current certification and compliance documentation available upon request. Please specify your target market and end-use application — we'll match the appropriate documentation package.
| Type | Inverter Generator |
| Frequency/Hz | 50 |
| Rated Voltage/V | 230 |
| Rated Power Output/KW | 2500W |
| Max Power Output/KW | 2800W |
| Power facter | 1.0 |
| Performance Grade | G1 |
| AC output quality | ISO8528 G1 |
| Waveform distortion rate/% | ≤3% |
| Noise level(at 7m) | ≤97db |
| Overload protection AC | Frequency converter overcurrent protection program control |
| Operating Altitude | ≤1000m |
| Engine Model | HH168-2 |
| Engine Type | Single cylinder,Four stroke,Forced air cooling,Overhead valve |
| Displacement(CC) | 196CC |
| Fuel Type | Unleaded gasoline |
| Fuel Tank capacity/L | 5.5L |
| Continuous operating time(at rated output) | 3h |
| Engine oil volume/L | 0.6L |
| lgnition plug model | F7RTC/FTTC |
| Starting system | Manual start/Electric start |
| Dimension(L*W*H/mm) | 470*390*470mm |
| Net Weight | 24.3kg |